According to DIN EN ISO 17892-6, -12, BS 1337-2. To determine the state limit of soils.
- Scope of delivery
- Frame with base plate and height adjustable measuring arm
Device for manually releasing drop bar
Analog dial gauge: dia. 100 mm; measurement path 50 mm, accuracy 0.01 mm
Drop bar: 49 g
Stainless steel cone: 30° for drop cone test 80 g - Dimensions
- (W x D x H) = 250 x 400 x 600 mm
Weight: 15 kg